Sourcing B2B d’équipements de laboratoire Coordination fournisseurs · Clarification technique · Support export
Électrofilage et préparation de fibres

LS-12 Temperature-Controlled Electrospinning Machine

ModèleLS-12

Laboratory electrospinning machine with 0 to +30 kV output, precision syringe feeding and drum/flat collectors. Chamber heating up to 65°C.

High-voltage range 0 to +30 kV
Flow range 0.01-999.99 mL/h
Temperature range Ambient to 65°C
  • Configuration finale confirmée avant devis
  • Personnalisation et accessoires étudiés selon l’application
  • Emballage export et documentation disponibles sur demande
Applications typiques
  • Single-needle and multi-needle electrospinning
  • Coaxial electrospinning
Caractéristiques de l’équipement

Principales caractéristiques

  • Independent feeding parameters and timed stop

  • 120-3000 rpm drum and 20 × 20 cm flat collector

  • 0-200 mm nozzle traverse

  • Temperature control with external dehumidification configuration

Données techniques

Spécifications techniques

Les spécifications sont organisées par système afin de présenter les paramètres pertinents pour chaque équipement.

Electrical and high voltage

High-voltage range 0 to +30 kV
Voltage control Continuous knob adjustment; digital readout
High-voltage output <30 W; <1 mA

Optional configurations

Optional high voltage 0 to +50 kV or negative high voltage; confirm configuration
External dehumidifier 800 W module; optional

Solution feeding

Pump configuration Two pumps with independently set parameters
Flow range 0.01-999.99 mL/h
Stated flow precision 0.01 mL/h
Pump control 4.2 in touchscreen
Compatible syringe volumes 1, 5, 10, 20, 30, 50, 60 mL
Parameter memory Four non-standard syringe profiles; timed stop

Collection and motion

Drum collector 120-3000 rpm; diameter 89 mm; length 200 mm
Stated drum speed precision 1 rpm
Flat collector 20 × 20 cm mirror-finish stainless steel
Y-axis traverse 0-200 mm; 0-1500 mm/min; stated precision 1 mm/min
Spinneret support Folding, three-joint angle adjustment

Enclosure and environment

Temperature range Ambient to 65°C
Stated temperature precision 0.2°C
Heating method Carbon-fibre infrared heating

General specifications

Power supply 220 V AC
Maximum power 1900 W
Dimensions 80 × 60 × 110 cm

Les spécifications peuvent varier selon la configuration. Les données finales dépendent du devis confirmé.

Humidity configuration

  • The catalogue describes dehumidification under ambient humidity above 80% RH. The achievable chamber humidity depends on ambient conditions; confirm it for the required process.

Listed accessories

  • 150 single needles; one multi-needle spinneret; one coaxial spinneret
  • 21-25G needles, 30 of each size; 5/10/20 mL syringes, 30 of each size
  • 15 pairs of Luer connectors, 15 m tubing, 50 release-paper sheets, 10 m aluminium foil, one power strip and one cleaning rod; 20 mL spinning solution

Enclosure

  • Corrosion-resistant and high-voltage-resistant inner lining, transparent viewing windows, exhaust fan, illumination and observation lights, anti-static observation board, combination lock and nozzle-cleaning window.

Configuration variants

  • The catalogue offers versions with and without the external dehumidifier. Specify the required version when requesting a quotation.