Électrofilage et préparation de fibres
LS-12 Temperature-Controlled Electrospinning Machine
ModèleLS-12
Laboratory electrospinning machine with 0 to +30 kV output, precision syringe feeding and drum/flat collectors. Chamber heating up to 65°C.
High-voltage range
0 to +30 kV
Flow range
0.01-999.99 mL/h
Temperature range
Ambient to 65°C
- Configuration finale confirmée avant devis
- Personnalisation et accessoires étudiés selon l’application
- Emballage export et documentation disponibles sur demande
Contact technique direct
Applications typiques
- Single-needle and multi-needle electrospinning
- Coaxial electrospinning
Caractéristiques de l’équipement
Principales caractéristiques
-
Independent feeding parameters and timed stop
-
120-3000 rpm drum and 20 × 20 cm flat collector
-
0-200 mm nozzle traverse
-
Temperature control with external dehumidification configuration
Données techniques
Spécifications techniques
Les spécifications sont organisées par système afin de présenter les paramètres pertinents pour chaque équipement.
Electrical and high voltage
| High-voltage range | 0 to +30 kV |
|---|---|
| Voltage control | Continuous knob adjustment; digital readout |
| High-voltage output | <30 W; <1 mA |
Optional configurations
| Optional high voltage | 0 to +50 kV or negative high voltage; confirm configuration |
|---|---|
| External dehumidifier | 800 W module; optional |
Solution feeding
| Pump configuration | Two pumps with independently set parameters |
|---|---|
| Flow range | 0.01-999.99 mL/h |
| Stated flow precision | 0.01 mL/h |
| Pump control | 4.2 in touchscreen |
| Compatible syringe volumes | 1, 5, 10, 20, 30, 50, 60 mL |
| Parameter memory | Four non-standard syringe profiles; timed stop |
Collection and motion
| Drum collector | 120-3000 rpm; diameter 89 mm; length 200 mm |
|---|---|
| Stated drum speed precision | 1 rpm |
| Flat collector | 20 × 20 cm mirror-finish stainless steel |
| Y-axis traverse | 0-200 mm; 0-1500 mm/min; stated precision 1 mm/min |
| Spinneret support | Folding, three-joint angle adjustment |
Enclosure and environment
| Temperature range | Ambient to 65°C |
|---|---|
| Stated temperature precision | 0.2°C |
| Heating method | Carbon-fibre infrared heating |
General specifications
| Power supply | 220 V AC |
|---|---|
| Maximum power | 1900 W |
| Dimensions | 80 × 60 × 110 cm |
Les spécifications peuvent varier selon la configuration. Les données finales dépendent du devis confirmé.
Contact technique direct
Humidity configuration
- The catalogue describes dehumidification under ambient humidity above 80% RH. The achievable chamber humidity depends on ambient conditions; confirm it for the required process.
Listed accessories
- 150 single needles; one multi-needle spinneret; one coaxial spinneret
- 21-25G needles, 30 of each size; 5/10/20 mL syringes, 30 of each size
- 15 pairs of Luer connectors, 15 m tubing, 50 release-paper sheets, 10 m aluminium foil, one power strip and one cleaning rod; 20 mL spinning solution
Enclosure
- Corrosion-resistant and high-voltage-resistant inner lining, transparent viewing windows, exhaust fan, illumination and observation lights, anti-static observation board, combination lock and nozzle-cleaning window.
Configuration variants
- The catalogue offers versions with and without the external dehumidifier. Specify the required version when requesting a quotation.
Les détails d’achat peuvent être confirmés avant commande.
Confirmer les besoins
Pour les acheteurs internationaux, la confirmation du devis peut inclure configuration, accessoires, emballage, documents export, photos ou vidéos d’inspection et conditions d’expédition.
Équipements associés