Électrofilage et préparation de fibres
LS-04 Conjugate Electrospinning Machine
ModèleLS-04
Four-pump conjugate electrospinning system with bipolar high voltage, six collector types and dual independent traverse axes for fiber, tube and yarn experiments.
High-voltage range
-30 to +30 kV
Flow range
0.01-999.99 mL/h
Temperature range
Ambient to 65°C; stated precision 0.2°C
- Configuration finale confirmée avant devis
- Personnalisation et accessoires étudiés selon l’application
- Emballage export et documentation disponibles sur demande
Contact technique direct
Applications typiques
- Aligned fiber collection
- 1-6 mm nanofiber tubes
- Nanofiber yarn and core-spun yarn
Caractéristiques de l’équipement
Principales caractéristiques
-
Four independently controlled feed pumps
-
10-inch touchscreen with 20 parameter presets
-
Six collector configurations
-
Dual Y axes with independent or synchronized movement
Données techniques
Spécifications techniques
Les spécifications sont organisées par système afin de présenter les paramètres pertinents pour chaque équipement.
Electrical and high voltage
| High-voltage range | -30 to +30 kV |
|---|---|
| High-voltage output | <30 W; <1 mA |
General specifications
| Main control | 10-inch touchscreen; HZ-V4.1; 20 parameter presets |
|---|---|
| Power supply | 220 V AC |
| Maximum power | 2000 W |
| Dimensions | 120 × 88 × 115 cm |
Solution feeding
| Pump configuration | Four independently controlled pumps |
|---|---|
| Flow range | 0.01-999.99 mL/h |
| Stated flow precision | 0.01 mL/h |
| Pump control | 4.2 in touchscreen |
| Compatible syringe volumes | 1, 5, 10, 20, 30, 50, 60 mL |
| Parameter memory | Four non-standard syringe profiles; timed stop |
Collection and motion
| Drum collector | 1-3000 rpm; diameter 89 mm; length 200 mm; stated precision 1 rpm |
|---|---|
| Collector types | Drum, 12-electrode cage, narrow drum, flat plate, mandrel, yarn collector |
| Flat collector | 20 × 20 cm stainless steel |
| Nanofiber tube diameter | 1-6 mm |
| Dual Y-axis travel | 0-200 mm |
| Traverse speed | 0-1000 mm/min; stated precision 1 mm/min |
Enclosure and environment
| Temperature range | Ambient to 65°C; stated precision 0.2°C |
|---|---|
| External dehumidifier | 800 W module |
Les spécifications peuvent varier selon la configuration. Les données finales dépendent du devis confirmé.
Contact technique direct
Humidity configuration
- The catalogue describes dehumidification under ambient humidity above 80% RH. The achievable chamber humidity depends on ambient conditions; confirm it for the required process.
Listed accessories
- 150 single needles; one multi-needle spinneret; one coaxial spinneret
- 21-25G needles, 30 of each size; 5/10/20 mL syringes, 30 of each size
- 15 pairs of Luer connectors, 15 m tubing, 50 release-paper sheets, 10 m aluminium foil, one power strip and one cleaning rod; 20 mL spinning solution
- One Janus side-by-side spinneret (19/19)
- One air-assisted spinning head set
Safety configuration
- Overtemperature protection, solvent exhaust, high-voltage overcurrent/short-circuit protection, grounding, combination lock, emergency stop and fuses.
Les détails d’achat peuvent être confirmés avant commande.
Confirmer les besoins
Pour les acheteurs internationaux, la confirmation du devis peut inclure configuration, accessoires, emballage, documents export, photos ou vidéos d’inspection et conditions d’expédition.
Équipements associés