ModèleLS-04

Four-pump conjugate electrospinning system with bipolar high voltage, six collector types and dual independent traverse axes for fiber, tube and yarn experiments.

High-voltage range -30 to +30 kV
Flow range 0.01-999.99 mL/h
Temperature range Ambient to 65°C; stated precision 0.2°C
  • Configuration finale confirmée avant devis
  • Personnalisation et accessoires étudiés selon l’application
  • Emballage export et documentation disponibles sur demande
Applications typiques
  • Aligned fiber collection
  • 1-6 mm nanofiber tubes
  • Nanofiber yarn and core-spun yarn
Caractéristiques de l’équipement

Principales caractéristiques

  • Four independently controlled feed pumps

  • 10-inch touchscreen with 20 parameter presets

  • Six collector configurations

  • Dual Y axes with independent or synchronized movement

Données techniques

Spécifications techniques

Les spécifications sont organisées par système afin de présenter les paramètres pertinents pour chaque équipement.

Electrical and high voltage

High-voltage range -30 to +30 kV
High-voltage output <30 W; <1 mA

General specifications

Main control 10-inch touchscreen; HZ-V4.1; 20 parameter presets
Power supply 220 V AC
Maximum power 2000 W
Dimensions 120 × 88 × 115 cm

Solution feeding

Pump configuration Four independently controlled pumps
Flow range 0.01-999.99 mL/h
Stated flow precision 0.01 mL/h
Pump control 4.2 in touchscreen
Compatible syringe volumes 1, 5, 10, 20, 30, 50, 60 mL
Parameter memory Four non-standard syringe profiles; timed stop

Collection and motion

Drum collector 1-3000 rpm; diameter 89 mm; length 200 mm; stated precision 1 rpm
Collector types Drum, 12-electrode cage, narrow drum, flat plate, mandrel, yarn collector
Flat collector 20 × 20 cm stainless steel
Nanofiber tube diameter 1-6 mm
Dual Y-axis travel 0-200 mm
Traverse speed 0-1000 mm/min; stated precision 1 mm/min

Enclosure and environment

Temperature range Ambient to 65°C; stated precision 0.2°C
External dehumidifier 800 W module

Les spécifications peuvent varier selon la configuration. Les données finales dépendent du devis confirmé.

Humidity configuration

  • The catalogue describes dehumidification under ambient humidity above 80% RH. The achievable chamber humidity depends on ambient conditions; confirm it for the required process.

Listed accessories

  • 150 single needles; one multi-needle spinneret; one coaxial spinneret
  • 21-25G needles, 30 of each size; 5/10/20 mL syringes, 30 of each size
  • 15 pairs of Luer connectors, 15 m tubing, 50 release-paper sheets, 10 m aluminium foil, one power strip and one cleaning rod; 20 mL spinning solution
  • One Janus side-by-side spinneret (19/19)
  • One air-assisted spinning head set

Safety configuration

  • Overtemperature protection, solvent exhaust, high-voltage overcurrent/short-circuit protection, grounding, combination lock, emergency stop and fuses.