B2B laboratory equipment sourcing Supplier coordination · Technical clarification · Export support
Electrospinning and Fiber Preparation

LS-04 Conjugate Electrospinning Machine

ModelLS-04

Four-pump conjugate electrospinning system with bipolar high voltage, six collector types and dual independent traverse axes for fiber, tube and yarn experiments.

High-voltage range -30 to +30 kV
Flow range 0.01-999.99 mL/h
Temperature range Ambient to 65°C; stated precision 0.2°C
  • Final configuration confirmed before quotation
  • Customization and accessories reviewed by application
  • Export packing and documentation available on request
Typical applications
  • Aligned fiber collection
  • 1-6 mm nanofiber tubes
  • Nanofiber yarn and core-spun yarn
Equipment features

Key product features

  • Four independently controlled feed pumps

  • 10-inch touchscreen with 20 parameter presets

  • Six collector configurations

  • Dual Y axes with independent or synchronized movement

Technical data

Technical specifications

Specifications are organized by system so different equipment types can present the parameters that matter for their application.

Electrical and high voltage

High-voltage range -30 to +30 kV
High-voltage output <30 W; <1 mA

General specifications

Main control 10-inch touchscreen; HZ-V4.1; 20 parameter presets
Power supply 220 V AC
Maximum power 2000 W
Dimensions 120 × 88 × 115 cm

Solution feeding

Pump configuration Four independently controlled pumps
Flow range 0.01-999.99 mL/h
Stated flow precision 0.01 mL/h
Pump control 4.2 in touchscreen
Compatible syringe volumes 1, 5, 10, 20, 30, 50, 60 mL
Parameter memory Four non-standard syringe profiles; timed stop

Collection and motion

Drum collector 1-3000 rpm; diameter 89 mm; length 200 mm; stated precision 1 rpm
Collector types Drum, 12-electrode cage, narrow drum, flat plate, mandrel, yarn collector
Flat collector 20 × 20 cm stainless steel
Nanofiber tube diameter 1-6 mm
Dual Y-axis travel 0-200 mm
Traverse speed 0-1000 mm/min; stated precision 1 mm/min

Enclosure and environment

Temperature range Ambient to 65°C; stated precision 0.2°C
External dehumidifier 800 W module

Specifications may change with configuration and customization. Final data is subject to the confirmed quotation.

Humidity configuration

  • The catalogue describes dehumidification under ambient humidity above 80% RH. The achievable chamber humidity depends on ambient conditions; confirm it for the required process.

Listed accessories

  • 150 single needles; one multi-needle spinneret; one coaxial spinneret
  • 21-25G needles, 30 of each size; 5/10/20 mL syringes, 30 of each size
  • 15 pairs of Luer connectors, 15 m tubing, 50 release-paper sheets, 10 m aluminium foil, one power strip and one cleaning rod; 20 mL spinning solution
  • One Janus side-by-side spinneret (19/19)
  • One air-assisted spinning head set

Safety configuration

  • Overtemperature protection, solvent exhaust, high-voltage overcurrent/short-circuit protection, grounding, combination lock, emergency stop and fuses.